Audio (5)
Front Mic Power frontMicPower Set/Get Front Mic Power
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Mic 2 Input Select mic2InputSelect Set/Get Mic Amp
OptionList Simple
Control & Feedback
Control: Options
0: OFF
1: FRONT_MIC
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 2 opts
Options by Model
AK-UCU600 (2 options)
0: OFF
1: FRONT_MIC
Mic Amp micAmp Set/Get Mic Amp
Integer Simple
Control & Feedback
Control: Integer [-20:20]dB
Feedback: Normal (Same as Control)
Dimensions
Mic (2 elements)
1: Mic 1
2: Mic 2
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-20:20]
Mic Gain micGain Set/Get Mic Gain
OptionList Simple
Control & Feedback
Control: Options
0: 20
1: 40
2: 60
Feedback: Normal (Same as Control)
Dimensions
Mic (2 elements)
1: Mic 1
2: Mic 2
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 3 opts
Options by Model
AK-UCU600 (3 options)
0: 20
1: 40
2: 60
Mic Input Level micInputLevel Set/Get Mic Input Level
OptionList Simple
Control & Feedback
Control: Options
0: 0
1: 4
Feedback: Normal (Same as Control)
Dimensions
Mic (2 elements)
1: Mic 1
2: Mic 2
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 2 opts
Options by Model
AK-UCU600 (2 options)
0: 0
1: 4
Commands (1)
KeepAlive KeepAlive KeepAlive KeepAlive
Trigger Helper
Control & Feedback
Control: One-Shot Trigger
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Oneshot None -
config (1)
Connection connection Connection status of device
On/Off
Control & Feedback
Control: None
Feedback: Binary (On/Off)
Model Support
Model Control Feedback Range/Type
AK-UCU600 None Normal On/Off
Detail (2)
DNR Enable dnrEnable Set/Get DNR Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
DNR Level dnrLevel Set/Get DNR Level
Integer Simple
Control & Feedback
Control: Integer [1:5]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [1:5]
Flare (3)
Color Flare colorFlare Set/Get Color Flare
Integer Simple
Control & Feedback
Control: Integer [-200:200]
Feedback: Normal (Same as Control)
Dimensions
Color (3 elements)
1: Red
2: Green
3: Blue
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-200:200]
Flare Enable flareEnable Set/Get Flare Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Master Flare masterFlare Set/Get Master Flare
Integer Simple
Control & Feedback
Control: Integer [-200:200]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-200:200]
Knee (10)
HLG Knee (3)
HLG Knee Enable hlgKneeEnable Set/Get HLG Knee enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
HLG Knee Point hlgKneePoint Set/Get HLG Knee Point
Float Simple
Control & Feedback
Control: Float [60.00:100.00]
Feedback: Delayed
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Delayed [60.00:100.00]
HLG Knee Slope hlgKneeSlope Set/Get HLG Knee Slope
Integer Simple
Control & Feedback
Control: Integer [0:199]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [0:199]
Blue Knee Point blueKneePoint Set/Get Blue Knee Point
Float Simple
Control & Feedback
Control: Float [-25.00:25.00]
Feedback: Delayed
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Delayed [-25.00:25.00]
Blue Knee Slope blueKneeSlope Set/Get Blue Knee Slope
Integer Simple
Control & Feedback
Control: Integer [-99:99]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-99:99]
Knee Control Enable kneeControlEnable Set/Get Knee Control Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Knee Master Point kneeMasterPoint Set/Get Knee Master Point
Float Simple
Control & Feedback
Control: Float [80.00:110.00]
Feedback: Delayed
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Delayed [80.00:110.00]
Knee Master Slope kneeMasterSlope Set/Get Knee Master Slope
Integer Simple
Control & Feedback
Control: Integer [0:199]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [0:199]
Red Knee Point redKneePoint Set/Get Red Knee Point
Float Simple
Control & Feedback
Control: Float [-25.00:25.00]
Feedback: Delayed
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Delayed [-25.00:25.00]
Red Knee Slope redKneeSlope Set/Get Red Knee Slope
Integer Simple
Control & Feedback
Control: Integer [-99:99]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-99:99]
Lens (13)
Auto Range autoRange Set/Get Auto Range
OptionList Simple
Control & Feedback
Control: Options
0: Norm
1: (3/4)
2: (2/4)
3: (1/4)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 4 opts
Options by Model
AK-UCU600 (4 options)
0: Norm
1: (3/4)
2: (2/4)
3: (1/4)
CC Filter ccFilter Set/Get CC Filter
OptionList Simple
Control & Feedback
Control: Options
0: A
1: B
2: C
3: D
4: E
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 5 opts
Options by Model
AK-UCU600 (5 options)
0: A
1: B
2: C
3: D
4: E
F Number position fNumberPosition Get Iris F number
Float Simple
Control & Feedback
Control: None
Feedback: Float F[0.0:255.0]
Model Support
Model Control Feedback Range/Type
AK-UCU600 None Normal [0.00:255.00]
Iris iris Set/Get Iris
Integer Simple
Control & Feedback
Control: Integer [0:10000] (dynamic)
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal None [0:10000]
Iris Auto irisAuto Set/Get Iris Auto
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Iris Level irisLevel Set/Get Iris Level
Integer Simple
Control & Feedback
Control: Integer [1:100]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [1:100]
Iris Max irisMax Set and store Iris Max position
Integer Simple
Control & Feedback
Control: Integer [5000:10000]
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal None [5000:10000]
Iris Min irisMin Set and store Iris Min position
Integer Simple
Control & Feedback
Control: Integer [0:5000]
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal None [0:5000]
Iris Speed irisSpeed Set/Get Iris Speed
Integer Simple
Control & Feedback
Control: Integer [1:25]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [1:25]
ND Filter ndFilter Set/Get ND Filter
OptionList Simple
Control & Feedback
Control: Options
0: 1
1: 2
2: 3
3: 4
4: 5
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 5 opts
Options by Model
AK-UCU600 (5 options)
0: 1
1: 2
2: 3
3: 4
4: 5
Peek peek Set/Get Peek
Integer Simple
Control & Feedback
Control: Integer [1:100]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [1:100]
Window window Set/Get Window
Integer Simple
Control & Feedback
Control: Integer [1:4]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [1:4]
Zoom Focus Rmt zoomFocusRmt Set/Get Zoom Focus Rmt
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Paint (31)
Black Gamma (4)
Black Gamma Enable blackGammaEnable Set/Get Black Gamma Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Blue Black Gamma blueBlackGamma Set/Get Black Blue Gamma
Integer Simple
Control & Feedback
Control: Integer [-20:20]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-20:20]
Master Black Gamma masterBlackGamma Set/Get Master Black Gamma
Integer Simple
Control & Feedback
Control: Integer [-48:48]
Feedback: Delayed
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Delayed [-48:48]
Red Black Gamma redBlackGamma Set/Get Black Red Gamma
Integer Simple
Control & Feedback
Control: Integer [-20:20]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-20:20]
Color Correction (4)
Color Correction Enable colorCorrectionEnable Set/Get Color Correction Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Color Correction Table colorCorrectionTable Set/Get Color Correction Table
OptionList Simple
Control & Feedback
Control: Options
0: A
1: B
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 2 opts
Options by Model
AK-UCU600 (2 options)
0: A
1: B
Phases phases Set/Get Phases with Phases types
Integer Simple
Control & Feedback
Control: Integer [-127:127]
Feedback: Normal (Same as Control)
Dimensions
(12 elements)
1: Phase R
2: Phase R-Mg
3: Phase Mg
4: Phase Mg-B
5: Phase B
6: Phase B-Cy
7: Phase Cy
8: Phase Cy-G
9: Phase G
10: Phase G-Yl
11: Phase Yl
12: Phase Yl-R
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-127:127]
Saturations saturations Set/Get Saturations with saturation types
Integer Simple
Control & Feedback
Control: Integer [-127:126]
Feedback: Normal (Same as Control)
Dimensions
(12 elements)
1: Saturation R
2: Saturation R-Mg
3: Saturation Mg
4: Saturation Mg-B
5: Saturation B
6: Saturation B-Cy
7: Saturation Cy
8: Saturation Cy-G
9: Saturation G
10: Saturation G-Yl
11: Saturation Yl
12: Saturation Yl-R
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-127:126]
Color Temp (3)
Color Temp colorTemp Set/Get Color Temp
Integer Simple
Control & Feedback
Control: None
Feedback: Integer [2000:99999]
Model Support
Model Control Feedback Range/Type
AK-UCU600 None Normal [2000:99999]
Color Temp Enable colorTempEnable Change Color Temp Preset on/off
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Color Temp Setting colorTempSetting Change Color Temp Preset Settings
Integer
Control & Feedback
Control: Integer [-400:400]
Feedback: Normal (Same as Control)
Dimensions
Axis (3 elements)
1: R Gain
2: B Gain
3: G Axis
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-400:400]
Gain (1)
Gain gain Set/Get Gain value
Integer Simple
Control & Feedback
Control: Integer [-1000:1000]
Feedback: Normal (Same as Control)
Dimensions
Color (3 elements)
1: Red
2: Green
3: Blue
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-1000:1000]
Gamma (4)
Blue Gamma blueGamma Set/Get blue Gamma
Integer Simple
Control & Feedback
Control: Integer [-75:75]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-75:75]
Gamma Enable gammaEnable Set/Get Gamma Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Master Gamma masterGamma Set/Get Master Gamma
Float Simple
Control & Feedback
Control: Float [0.15:0.75]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [0.15:0.75]
Red Gamma redGamma Set/Get Red Gamma
Integer Simple
Control & Feedback
Control: Integer [-75:75]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-75:75]
Matrix (5)
Linear Matrix Enable linearMatrixEnable Set/Get Linear Matrix Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Liniear Table linearTable Set/Get Liniear Table
OptionList Simple
Control & Feedback
Control: Options
0: A
1: B
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 2 opts
Options by Model
AK-UCU600 (2 options)
0: A
1: B
Matrix Enable matrixEnable Set/Get Matrix Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Matrixs matrixs Set/Get Matrixs with Matrixs types
Integer Simple
Control & Feedback
Control: Integer [-31:31]
Feedback: Normal (Same as Control)
Dimensions
(12 elements)
1: Matrix R-G_N
2: Matrix R-G_P
3: Matrix R-B_N
4: Matrix R-B_P
5: Matrix G-R_N
6: Matrix G-R_P
7: Matrix G-B_N
8: Matrix G-B_P
9: Matrix B-R_N
10: Matrix B-R_P
11: Matrix B-G_N
12: Matrix B-G_P
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-31:31]
Preset Matrix presetMatrix Set/Get Preset Matrix
OptionList Simple
Control & Feedback
Control: Options
0: Norm
1: Ebu
2: Ntsc
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 3 opts
Options by Model
AK-UCU600 (3 options)
0: Norm
1: Ebu
2: Ntsc
PED (2)
Master Pedestal masterPedestal Set/Get Master Pedestal
Integer Simple
Control & Feedback
Control: Integer [-99:99]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-99:99]
Color Pedestal masterPedestalColor Set/Get Color Pedestal
Integer Simple
Control & Feedback
Control: Integer [-800:800]
Feedback: Normal (Same as Control)
Dimensions
Color (3 elements)
1: Red
2: Green
3: Blue
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-800:800]
Skin (4)
Skin Enable skinAreaEnable Set/Get Skin Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Skin Area Hue skinAreaHue Set/Get Skin Area Hue
Integer Simple
Control & Feedback
Control: Integer [-127:127]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-127:127]
Skin Area Table skinAreaTable Set/Get Skin Area Table
OptionList Simple
Control & Feedback
Control: Options
0: A
1: B
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 2 opts
Options by Model
AK-UCU600 (2 options)
0: A
1: B
Skin Area Tone skinAreaTone Set/Get Skin Area Tone
Integer Simple
Control & Feedback
Control: Integer [-127:126]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-127:126]
ABB set mode abbSetMode Set/Get ABB set mode
OptionList Simple
Control & Feedback
Control: Options
0: Mode1
1: Mode2
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 2 opts
Options by Model
AK-UCU600 (2 options)
0: Mode1
1: Mode2
Auto Black Balance (Abb) autoBlackBalance Perform Auto Black Balance (Abb)
Trigger Simple
Control & Feedback
Control: One-Shot Trigger
Feedback: None
Dimensions
Type (2 elements)
1: Active
2: Break
Model Support
Model Control Feedback Range/Type
AK-UCU600 Oneshot None -
Auto White Balance (Awb) autoWhiteBalance Perform Auto White Balance(Awb)
Trigger Simple
Control & Feedback
Control: One-Shot Trigger
Feedback: None
Dimensions
Type (2 elements)
1: Active
2: Break
Model Support
Model Control Feedback Range/Type
AK-UCU600 Oneshot None -
AWB set mode awbSetMode Set/Get AWB set mode
OptionList Simple
Control & Feedback
Control: Options
0: Mode1
1: Mode2
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 2 opts
Options by Model
AK-UCU600 (2 options)
0: Mode1
1: Mode2
Shutter (4)
Shutter Enable shutterEnable Set/Get Shutter Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Shutter Fix shutterFix Set/Get Shutter Fix
OptionList Simple
Control & Feedback
Control: Options
0: 60
1: 100
2: 125
3: 250
4: 500
5: 1000
6: 1500
7: 2000
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 8 opts
Options by Model
AK-UCU600 (8 options)
0: 60
1: 100
2: 125
3: 250
4: 500
5: 1000
6: 1500
7: 2000
Shutter Scan shutterScan Set/Get Shutter Scan
Integer Simple
Control & Feedback
Control: Integer [25:6130]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [25:6130]
Shutter Select shutterSelect Set/Get Shutter Select
OptionList Simple
Control & Feedback
Control: Options
0: SHUT
1: SCAN
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal 2 opts
Options by Model
AK-UCU600 (2 options)
0: SHUT
1: SCAN
System (25)
Clip (4)
Blue White Clip blueWhiteClipLevel Set/Get Blue White Clip
Integer Simple
Control & Feedback
Control: Integer [-15:15]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-15:15]
Red White Clip redWhiteClipLevel Set/Get Red White Clip
Integer Simple
Control & Feedback
Control: Integer [-15:15]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [-15:15]
White Clip Enable whiteClipEnable Set/Get White Clip Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
White Clip Level whiteClipLevel Set/Get White Clip Level
Integer Simple
Control & Feedback
Control: Integer [80:109]%
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [80:109]
Format (5)
Cam Number camNumber Get Cam Number
Integer
Control & Feedback
Control: None
Feedback: Integer [1:99]
Model Support
Model Control Feedback Range/Type
AK-UCU600 None Normal [1:99]
CCU Mode ccuMode Get CCU Mode
String
Control & Feedback
Control: None
Feedback: String
Model Support
Model Control Feedback Range/Type
AK-UCU600 None Normal String
Format format Get Format
OptionList Simple
Control & Feedback
Control: Options
0: 2160/59.94p
1: 2160/50p
2: 2160/29.97p
3: 2160/25p
4: 2160/23.98p
5: 1080/59.94p
6: 1080/50p
7: 1080/29.97p
8: 1080/25p
9: 1080/23.98p
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal None 10 opts
Options by Model
AK-UCU600 (10 options)
0: 2160/59.94p
1: 2160/50p
2: 2160/29.97p
3: 2160/25p
4: 2160/23.98p
5: 1080/59.94p
6: 1080/50p
7: 1080/29.97p
8: 1080/25p
9: 1080/23.98p
Format Mode Status formatModeStatus Get Format Mode Status
String
Control & Feedback
Control: None
Feedback: String
Model Support
Model Control Feedback Range/Type
AK-UCU600 None Normal String
Format Status formatStatus Get Format Status
String Simple
Control & Feedback
Control: None
Feedback: String
Model Support
Model Control Feedback Range/Type
AK-UCU600 None Normal String
Menu (8)
Cam Menu (4)
Cam Menu camMenu Perform Cam Menu
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Delayed
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Delayed On/Off
Cam Menu CCW camMenuCcw Perform Cam Menu CCw
Trigger
Control & Feedback
Control: One-Shot Trigger
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Oneshot None -
Cam Menu CW camMenuCw Perform Cam Menu Cw
Trigger
Control & Feedback
Control: One-Shot Trigger
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Oneshot None -
Cam Menu Set camMenuSet Perform Cam Menu Set
Trigger Simple
Control & Feedback
Control: One-Shot Trigger
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Oneshot None -
CCU Menu (4)
CCU Menu ccuMenu Perform CCU Menu
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Delayed
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Delayed On/Off
CCU Menu CCW ccuMenuCcw Perform CCU Menu CCw
Trigger
Control & Feedback
Control: One-Shot Trigger
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Oneshot None -
CCU Menu CW ccuMenuCw Perform CCU Menu Cw
Trigger
Control & Feedback
Control: One-Shot Trigger
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Oneshot None -
CCU Menu Set ccuMenuSet Perform CCU Menu Set
Trigger Simple
Control & Feedback
Control: One-Shot Trigger
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Oneshot None -
Bars Enable barsEnable Set/Get Bars Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Call call Perform Call
Trigger Simple
Control & Feedback
Control: One-Shot Trigger
Feedback: None
Dimensions
State (2 elements)
1: On
2: Off
Model Support
Model Control Feedback Range/Type
AK-UCU600 Oneshot None -
Call Position callPosition Get Call Position
OptionList
Control & Feedback
Control: None
Feedback: Options
0: Off
1: Rear
2: Talent
3: Rear+Talent
Model Support
Model Control Feedback Range/Type
AK-UCU600 None Normal 4 opts
Options by Model
AK-UCU600 (4 options)
0: Off
1: Rear
2: Talent
3: Rear+Talent
Cam Power camPower Get Cam Power
OptionList Simple
Control & Feedback
Control: None
Feedback: Options
0: Off
1: On
2: Remote
Model Support
Model Control Feedback Range/Type
AK-UCU600 None Normal 3 opts
Options by Model
AK-UCU600 (3 options)
0: Off
1: On
2: Remote
Character Enable char Get/Set Character status
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
Character Cycle charCycle Cycle through different kinds of menus
Trigger Simple
Control & Feedback
Control: One-Shot Trigger
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Oneshot None -
Tally tally Get Tally
On/Off Simple
Control & Feedback
Control: None
Feedback: Binary (On/Off)
Dimensions
(3 elements)
1: Yellow
2: Red
3: Green
Model Support
Model Control Feedback Range/Type
AK-UCU600 None Normal On/Off
Test Saw Enable testSawEnable Set/Get Test Saw Enable
On/Off Simple
Control & Feedback
Control: Binary (On/Off)
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal On/Off
tests (1)
Device Test device_test DeviceTest: The test enables bars for 5 seconds and disables it again
Trigger Helper
Control & Feedback
Control: One-Shot Trigger
Feedback: None
Model Support
Model Control Feedback Range/Type
AK-UCU600 Oneshot None -
Video Gain (2)
Master Gain masterGain Set/Get Master Gain in raw value
Integer Simple
Control & Feedback
Control: Integer [0:14]
Feedback: Normal (Same as Control)
Model Support
Model Control Feedback Range/Type
AK-UCU600 Normal Normal [0:14]
Master Gain Value masterGainValue Get Master Gain Value in dB
Integer Simple
Control & Feedback
Control: None
Feedback: Integer [-6:36]dB
Model Support
Model Control Feedback Range/Type
AK-UCU600 None Normal [-6:36]