Parameter List
DeviceCore
Panasonic Studio Camera
core-panasonic-studio-camera - Version v1.0.3-pre3 · 98 parameters · 2 models
Press
/
to search
·
View table layout
×
All Models
▼
All Models
AK-UCU600 [released]
Generic Model [beta]
All Types
Simple Only
Helper Only
Expand All
Collapse All
▶
Audio
(5)
▶
Front Mic Power
frontMicPower
Set/Get Front Mic Power
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Mic 2 Input Select
mic2InputSelect
Set/Get Mic Amp
OptionList
Simple
Control & Feedback
Control:
Options
0:
OFF
1:
FRONT_MIC
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
2 opts
Options by Model
▶
AK-UCU600
(2 options)
0:
OFF
1:
FRONT_MIC
▶
Mic Amp
micAmp
Set/Get Mic Amp
Integer
Simple
Control & Feedback
Control:
Integer [-20:20]dB
Feedback:
Normal (Same as Control)
Dimensions
Mic
(2 elements)
1:
Mic 1
2:
Mic 2
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-20:20]
▶
Mic Gain
micGain
Set/Get Mic Gain
OptionList
Simple
Control & Feedback
Control:
Options
0:
20
1:
40
2:
60
Feedback:
Normal (Same as Control)
Dimensions
Mic
(2 elements)
1:
Mic 1
2:
Mic 2
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
3 opts
Options by Model
▶
AK-UCU600
(3 options)
0:
20
1:
40
2:
60
▶
Mic Input Level
micInputLevel
Set/Get Mic Input Level
OptionList
Simple
Control & Feedback
Control:
Options
0:
0
1:
4
Feedback:
Normal (Same as Control)
Dimensions
Mic
(2 elements)
1:
Mic 1
2:
Mic 2
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
2 opts
Options by Model
▶
AK-UCU600
(2 options)
0:
0
1:
4
▶
Commands
(1)
▶
KeepAlive
KeepAlive
KeepAlive KeepAlive
Trigger
Helper
Control & Feedback
Control:
One-Shot Trigger
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Oneshot
None
-
▶
config
(1)
▶
Connection
connection
Connection status of device
On/Off
Control & Feedback
Control:
None
Feedback:
Binary (On/Off)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
None
Normal
On/Off
▶
Detail
(2)
▶
DNR Enable
dnrEnable
Set/Get DNR Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
DNR Level
dnrLevel
Set/Get DNR Level
Integer
Simple
Control & Feedback
Control:
Integer [1:5]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[1:5]
▶
Flare
(3)
▶
Color Flare
colorFlare
Set/Get Color Flare
Integer
Simple
Control & Feedback
Control:
Integer [-200:200]
Feedback:
Normal (Same as Control)
Dimensions
Color
(3 elements)
1:
Red
2:
Green
3:
Blue
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-200:200]
▶
Flare Enable
flareEnable
Set/Get Flare Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Master Flare
masterFlare
Set/Get Master Flare
Integer
Simple
Control & Feedback
Control:
Integer [-200:200]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-200:200]
▶
Knee
(10)
▶
HLG Knee
(3)
▶
HLG Knee Enable
hlgKneeEnable
Set/Get HLG Knee enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
HLG Knee Point
hlgKneePoint
Set/Get HLG Knee Point
Float
Simple
Control & Feedback
Control:
Float [60.00:100.00]
Feedback:
Delayed
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Delayed
[60.00:100.00]
▶
HLG Knee Slope
hlgKneeSlope
Set/Get HLG Knee Slope
Integer
Simple
Control & Feedback
Control:
Integer [0:199]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[0:199]
▶
Blue Knee Point
blueKneePoint
Set/Get Blue Knee Point
Float
Simple
Control & Feedback
Control:
Float [-25.00:25.00]
Feedback:
Delayed
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Delayed
[-25.00:25.00]
▶
Blue Knee Slope
blueKneeSlope
Set/Get Blue Knee Slope
Integer
Simple
Control & Feedback
Control:
Integer [-99:99]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-99:99]
▶
Knee Control Enable
kneeControlEnable
Set/Get Knee Control Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Knee Master Point
kneeMasterPoint
Set/Get Knee Master Point
Float
Simple
Control & Feedback
Control:
Float [80.00:110.00]
Feedback:
Delayed
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Delayed
[80.00:110.00]
▶
Knee Master Slope
kneeMasterSlope
Set/Get Knee Master Slope
Integer
Simple
Control & Feedback
Control:
Integer [0:199]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[0:199]
▶
Red Knee Point
redKneePoint
Set/Get Red Knee Point
Float
Simple
Control & Feedback
Control:
Float [-25.00:25.00]
Feedback:
Delayed
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Delayed
[-25.00:25.00]
▶
Red Knee Slope
redKneeSlope
Set/Get Red Knee Slope
Integer
Simple
Control & Feedback
Control:
Integer [-99:99]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-99:99]
▶
Lens
(13)
▶
Auto Range
autoRange
Set/Get Auto Range
OptionList
Simple
Control & Feedback
Control:
Options
0:
Norm
1:
(3/4)
2:
(2/4)
3:
(1/4)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
4 opts
Options by Model
▶
AK-UCU600
(4 options)
0:
Norm
1:
(3/4)
2:
(2/4)
3:
(1/4)
▶
CC Filter
ccFilter
Set/Get CC Filter
OptionList
Simple
Control & Feedback
Control:
Options
0:
A
1:
B
2:
C
3:
D
4:
E
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
5 opts
Options by Model
▶
AK-UCU600
(5 options)
0:
A
1:
B
2:
C
3:
D
4:
E
▶
F Number position
fNumberPosition
Get Iris F number
Float
Simple
Control & Feedback
Control:
None
Feedback:
Float F[0.0:255.0]
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
None
Normal
[0.00:255.00]
▶
Iris
iris
Set/Get Iris
Integer
Simple
Control & Feedback
Control:
Integer [0:10000] (dynamic)
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
None
[0:10000]
▶
Iris Auto
irisAuto
Set/Get Iris Auto
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Iris Level
irisLevel
Set/Get Iris Level
Integer
Simple
Control & Feedback
Control:
Integer [1:100]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[1:100]
▶
Iris Max
irisMax
Set and store Iris Max position
Integer
Simple
Control & Feedback
Control:
Integer [5000:10000]
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
None
[5000:10000]
▶
Iris Min
irisMin
Set and store Iris Min position
Integer
Simple
Control & Feedback
Control:
Integer [0:5000]
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
None
[0:5000]
▶
Iris Speed
irisSpeed
Set/Get Iris Speed
Integer
Simple
Control & Feedback
Control:
Integer [1:25]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[1:25]
▶
ND Filter
ndFilter
Set/Get ND Filter
OptionList
Simple
Control & Feedback
Control:
Options
0:
1
1:
2
2:
3
3:
4
4:
5
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
5 opts
Options by Model
▶
AK-UCU600
(5 options)
0:
1
1:
2
2:
3
3:
4
4:
5
▶
Peek
peek
Set/Get Peek
Integer
Simple
Control & Feedback
Control:
Integer [1:100]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[1:100]
▶
Window
window
Set/Get Window
Integer
Simple
Control & Feedback
Control:
Integer [1:4]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[1:4]
▶
Zoom Focus Rmt
zoomFocusRmt
Set/Get Zoom Focus Rmt
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Paint
(31)
▶
Black Gamma
(4)
▶
Black Gamma Enable
blackGammaEnable
Set/Get Black Gamma Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Blue Black Gamma
blueBlackGamma
Set/Get Black Blue Gamma
Integer
Simple
Control & Feedback
Control:
Integer [-20:20]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-20:20]
▶
Master Black Gamma
masterBlackGamma
Set/Get Master Black Gamma
Integer
Simple
Control & Feedback
Control:
Integer [-48:48]
Feedback:
Delayed
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Delayed
[-48:48]
▶
Red Black Gamma
redBlackGamma
Set/Get Black Red Gamma
Integer
Simple
Control & Feedback
Control:
Integer [-20:20]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-20:20]
▶
Color Correction
(4)
▶
Color Correction Enable
colorCorrectionEnable
Set/Get Color Correction Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Color Correction Table
colorCorrectionTable
Set/Get Color Correction Table
OptionList
Simple
Control & Feedback
Control:
Options
0:
A
1:
B
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
2 opts
Options by Model
▶
AK-UCU600
(2 options)
0:
A
1:
B
▶
Phases
phases
Set/Get Phases with Phases types
Integer
Simple
Control & Feedback
Control:
Integer [-127:127]
Feedback:
Normal (Same as Control)
Dimensions
(12 elements)
1:
Phase R
2:
Phase R-Mg
3:
Phase Mg
4:
Phase Mg-B
5:
Phase B
6:
Phase B-Cy
7:
Phase Cy
8:
Phase Cy-G
9:
Phase G
10:
Phase G-Yl
11:
Phase Yl
12:
Phase Yl-R
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-127:127]
▶
Saturations
saturations
Set/Get Saturations with saturation types
Integer
Simple
Control & Feedback
Control:
Integer [-127:126]
Feedback:
Normal (Same as Control)
Dimensions
(12 elements)
1:
Saturation R
2:
Saturation R-Mg
3:
Saturation Mg
4:
Saturation Mg-B
5:
Saturation B
6:
Saturation B-Cy
7:
Saturation Cy
8:
Saturation Cy-G
9:
Saturation G
10:
Saturation G-Yl
11:
Saturation Yl
12:
Saturation Yl-R
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-127:126]
▶
Color Temp
(3)
▶
Color Temp
colorTemp
Set/Get Color Temp
Integer
Simple
Control & Feedback
Control:
None
Feedback:
Integer [2000:99999]
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
None
Normal
[2000:99999]
▶
Color Temp Enable
colorTempEnable
Change Color Temp Preset on/off
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Color Temp Setting
colorTempSetting
Change Color Temp Preset Settings
Integer
Control & Feedback
Control:
Integer [-400:400]
Feedback:
Normal (Same as Control)
Dimensions
Axis
(3 elements)
1:
R Gain
2:
B Gain
3:
G Axis
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-400:400]
▶
Gain
(1)
▶
Gain
gain
Set/Get Gain value
Integer
Simple
Control & Feedback
Control:
Integer [-1000:1000]
Feedback:
Normal (Same as Control)
Dimensions
Color
(3 elements)
1:
Red
2:
Green
3:
Blue
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-1000:1000]
▶
Gamma
(4)
▶
Blue Gamma
blueGamma
Set/Get blue Gamma
Integer
Simple
Control & Feedback
Control:
Integer [-75:75]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-75:75]
▶
Gamma Enable
gammaEnable
Set/Get Gamma Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Master Gamma
masterGamma
Set/Get Master Gamma
Float
Simple
Control & Feedback
Control:
Float [0.15:0.75]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[0.15:0.75]
▶
Red Gamma
redGamma
Set/Get Red Gamma
Integer
Simple
Control & Feedback
Control:
Integer [-75:75]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-75:75]
▶
Matrix
(5)
▶
Linear Matrix Enable
linearMatrixEnable
Set/Get Linear Matrix Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Liniear Table
linearTable
Set/Get Liniear Table
OptionList
Simple
Control & Feedback
Control:
Options
0:
A
1:
B
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
2 opts
Options by Model
▶
AK-UCU600
(2 options)
0:
A
1:
B
▶
Matrix Enable
matrixEnable
Set/Get Matrix Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Matrixs
matrixs
Set/Get Matrixs with Matrixs types
Integer
Simple
Control & Feedback
Control:
Integer [-31:31]
Feedback:
Normal (Same as Control)
Dimensions
(12 elements)
1:
Matrix R-G_N
2:
Matrix R-G_P
3:
Matrix R-B_N
4:
Matrix R-B_P
5:
Matrix G-R_N
6:
Matrix G-R_P
7:
Matrix G-B_N
8:
Matrix G-B_P
9:
Matrix B-R_N
10:
Matrix B-R_P
11:
Matrix B-G_N
12:
Matrix B-G_P
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-31:31]
▶
Preset Matrix
presetMatrix
Set/Get Preset Matrix
OptionList
Simple
Control & Feedback
Control:
Options
0:
Norm
1:
Ebu
2:
Ntsc
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
3 opts
Options by Model
▶
AK-UCU600
(3 options)
0:
Norm
1:
Ebu
2:
Ntsc
▶
PED
(2)
▶
Master Pedestal
masterPedestal
Set/Get Master Pedestal
Integer
Simple
Control & Feedback
Control:
Integer [-99:99]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-99:99]
▶
Color Pedestal
masterPedestalColor
Set/Get Color Pedestal
Integer
Simple
Control & Feedback
Control:
Integer [-800:800]
Feedback:
Normal (Same as Control)
Dimensions
Color
(3 elements)
1:
Red
2:
Green
3:
Blue
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-800:800]
▶
Skin
(4)
▶
Skin Enable
skinAreaEnable
Set/Get Skin Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Skin Area Hue
skinAreaHue
Set/Get Skin Area Hue
Integer
Simple
Control & Feedback
Control:
Integer [-127:127]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-127:127]
▶
Skin Area Table
skinAreaTable
Set/Get Skin Area Table
OptionList
Simple
Control & Feedback
Control:
Options
0:
A
1:
B
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
2 opts
Options by Model
▶
AK-UCU600
(2 options)
0:
A
1:
B
▶
Skin Area Tone
skinAreaTone
Set/Get Skin Area Tone
Integer
Simple
Control & Feedback
Control:
Integer [-127:126]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-127:126]
▶
ABB set mode
abbSetMode
Set/Get ABB set mode
OptionList
Simple
Control & Feedback
Control:
Options
0:
Mode1
1:
Mode2
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
2 opts
Options by Model
▶
AK-UCU600
(2 options)
0:
Mode1
1:
Mode2
▶
Auto Black Balance (Abb)
autoBlackBalance
Perform Auto Black Balance (Abb)
Trigger
Simple
Control & Feedback
Control:
One-Shot Trigger
Feedback:
None
Dimensions
Type
(2 elements)
1:
Active
2:
Break
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Oneshot
None
-
▶
Auto White Balance (Awb)
autoWhiteBalance
Perform Auto White Balance(Awb)
Trigger
Simple
Control & Feedback
Control:
One-Shot Trigger
Feedback:
None
Dimensions
Type
(2 elements)
1:
Active
2:
Break
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Oneshot
None
-
▶
AWB set mode
awbSetMode
Set/Get AWB set mode
OptionList
Simple
Control & Feedback
Control:
Options
0:
Mode1
1:
Mode2
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
2 opts
Options by Model
▶
AK-UCU600
(2 options)
0:
Mode1
1:
Mode2
▶
Shutter
(4)
▶
Shutter Enable
shutterEnable
Set/Get Shutter Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Shutter Fix
shutterFix
Set/Get Shutter Fix
OptionList
Simple
Control & Feedback
Control:
Options
0:
60
1:
100
2:
125
3:
250
4:
500
5:
1000
6:
1500
7:
2000
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
8 opts
Options by Model
▶
AK-UCU600
(8 options)
0:
60
1:
100
2:
125
3:
250
4:
500
5:
1000
6:
1500
7:
2000
▶
Shutter Scan
shutterScan
Set/Get Shutter Scan
Integer
Simple
Control & Feedback
Control:
Integer [25:6130]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[25:6130]
▶
Shutter Select
shutterSelect
Set/Get Shutter Select
OptionList
Simple
Control & Feedback
Control:
Options
0:
SHUT
1:
SCAN
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
2 opts
Options by Model
▶
AK-UCU600
(2 options)
0:
SHUT
1:
SCAN
▶
System
(25)
▶
Clip
(4)
▶
Blue White Clip
blueWhiteClipLevel
Set/Get Blue White Clip
Integer
Simple
Control & Feedback
Control:
Integer [-15:15]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-15:15]
▶
Red White Clip
redWhiteClipLevel
Set/Get Red White Clip
Integer
Simple
Control & Feedback
Control:
Integer [-15:15]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[-15:15]
▶
White Clip Enable
whiteClipEnable
Set/Get White Clip Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
White Clip Level
whiteClipLevel
Set/Get White Clip Level
Integer
Simple
Control & Feedback
Control:
Integer [80:109]%
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[80:109]
▶
Format
(5)
▶
Cam Number
camNumber
Get Cam Number
Integer
Control & Feedback
Control:
None
Feedback:
Integer [1:99]
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
None
Normal
[1:99]
▶
CCU Mode
ccuMode
Get CCU Mode
String
Control & Feedback
Control:
None
Feedback:
String
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
None
Normal
String
▶
Format
format
Get Format
OptionList
Simple
Control & Feedback
Control:
Options
0:
2160/59.94p
1:
2160/50p
2:
2160/29.97p
3:
2160/25p
4:
2160/23.98p
5:
1080/59.94p
6:
1080/50p
7:
1080/29.97p
8:
1080/25p
9:
1080/23.98p
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
None
10 opts
Options by Model
▶
AK-UCU600
(10 options)
0:
2160/59.94p
1:
2160/50p
2:
2160/29.97p
3:
2160/25p
4:
2160/23.98p
5:
1080/59.94p
6:
1080/50p
7:
1080/29.97p
8:
1080/25p
9:
1080/23.98p
▶
Format Mode Status
formatModeStatus
Get Format Mode Status
String
Control & Feedback
Control:
None
Feedback:
String
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
None
Normal
String
▶
Format Status
formatStatus
Get Format Status
String
Simple
Control & Feedback
Control:
None
Feedback:
String
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
None
Normal
String
▶
Menu
(8)
▶
Cam Menu
(4)
▶
Cam Menu
camMenu
Perform Cam Menu
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Delayed
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Delayed
On/Off
▶
Cam Menu CCW
camMenuCcw
Perform Cam Menu CCw
Trigger
Control & Feedback
Control:
One-Shot Trigger
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Oneshot
None
-
▶
Cam Menu CW
camMenuCw
Perform Cam Menu Cw
Trigger
Control & Feedback
Control:
One-Shot Trigger
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Oneshot
None
-
▶
Cam Menu Set
camMenuSet
Perform Cam Menu Set
Trigger
Simple
Control & Feedback
Control:
One-Shot Trigger
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Oneshot
None
-
▶
CCU Menu
(4)
▶
CCU Menu
ccuMenu
Perform CCU Menu
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Delayed
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Delayed
On/Off
▶
CCU Menu CCW
ccuMenuCcw
Perform CCU Menu CCw
Trigger
Control & Feedback
Control:
One-Shot Trigger
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Oneshot
None
-
▶
CCU Menu CW
ccuMenuCw
Perform CCU Menu Cw
Trigger
Control & Feedback
Control:
One-Shot Trigger
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Oneshot
None
-
▶
CCU Menu Set
ccuMenuSet
Perform CCU Menu Set
Trigger
Simple
Control & Feedback
Control:
One-Shot Trigger
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Oneshot
None
-
▶
Bars Enable
barsEnable
Set/Get Bars Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Call
call
Perform Call
Trigger
Simple
Control & Feedback
Control:
One-Shot Trigger
Feedback:
None
Dimensions
State
(2 elements)
1:
On
2:
Off
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Oneshot
None
-
▶
Call Position
callPosition
Get Call Position
OptionList
Control & Feedback
Control:
None
Feedback:
Options
0:
Off
1:
Rear
2:
Talent
3:
Rear+Talent
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
None
Normal
4 opts
Options by Model
▶
AK-UCU600
(4 options)
0:
Off
1:
Rear
2:
Talent
3:
Rear+Talent
▶
Cam Power
camPower
Get Cam Power
OptionList
Simple
Control & Feedback
Control:
None
Feedback:
Options
0:
Off
1:
On
2:
Remote
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
None
Normal
3 opts
Options by Model
▶
AK-UCU600
(3 options)
0:
Off
1:
On
2:
Remote
▶
Character Enable
char
Get/Set Character status
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
Character Cycle
charCycle
Cycle through different kinds of menus
Trigger
Simple
Control & Feedback
Control:
One-Shot Trigger
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Oneshot
None
-
▶
Tally
tally
Get Tally
On/Off
Simple
Control & Feedback
Control:
None
Feedback:
Binary (On/Off)
Dimensions
(3 elements)
1:
Yellow
2:
Red
3:
Green
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
None
Normal
On/Off
▶
Test Saw Enable
testSawEnable
Set/Get Test Saw Enable
On/Off
Simple
Control & Feedback
Control:
Binary (On/Off)
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
On/Off
▶
tests
(1)
▶
Device Test
device_test
DeviceTest: The test enables bars for 5 seconds and disables it again
Trigger
Helper
Control & Feedback
Control:
One-Shot Trigger
Feedback:
None
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Oneshot
None
-
▶
Video Gain
(2)
▶
Master Gain
masterGain
Set/Get Master Gain in raw value
Integer
Simple
Control & Feedback
Control:
Integer [0:14]
Feedback:
Normal (Same as Control)
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
Normal
Normal
[0:14]
▶
Master Gain Value
masterGainValue
Get Master Gain Value in dB
Integer
Simple
Control & Feedback
Control:
None
Feedback:
Integer [-6:36]dB
Model Support
Model
Control
Feedback
Range/Type
AK-UCU600
None
Normal
[-6:36]
No parameters match your search criteria.